> > > SANIMP Detailed outline

Data ONTAP SAN Implementation (SANIMP)

Course Description Schedule Course Outline

Detailed Course Outline

Module 1: SAN Concepts
  • NetApp SAN
  • SAN Protocols
  • SAN Terminology
  • Implementing SAN
  • Designing and Planning a SAN Solution
Module 2: IP SAN Architecture
  • IP SAN Architecture
  • iSCSI Protocol
  • Implementing IP SAN on Data ONTAP
  • Scaling IP SAN In clustered Data ONTAP
Module 3: Windows IP Connectivity
  • Windows iSCSI Configuration
  • Windows iSCSI Implementation
Module 4: Windows LUN
  • LUN Access Overview
  • Windows Setup
  • Volume Management
  • SnapDrive for Windows
Module 5: Linux IP Connectivity
  • Linux iSCSI Configuration
Module 6: Linux LUN
  • LUN Access Review
  • Linux Setup
  • Volume Management
Module 7: FC SAN Architecture
  • FC SAN Architecture
  • FC SAN Connections
  • FC Protocol
Module 8: FC SAN Fabrics
  • Fabric Design
  • FC Initialization
  • Switch Concepts
  • FC Zoning
  • Scaling FC SAN in clustered Data ONTAP
Module 9: Windows FC Connectivity
  • Windows FC Connectivity
  • Data ONTAP 7-Mode CF Modes
  • Windows Configuration
  • Discovery and Provisioning
Module 10: Unified Connect
  • Unified Connect
  • FCoE-Enabling Technologies
  • End-to-End FCoE Configuration
  • FC-to-FCoE Connectivity
Module 11: Linux FC
  • Linux FC Configuration
  • SnapDrive for Unix
Module 12: LUN Provisioning
  • LUN Provisioning
  • LUN Overwrite Reservations
  • SAN Provisioning Options
  • HOST-Side Space Management
  • Keeping LUNs Online
Module 13: Host Considerations
  • Common Disk Structures
  • Multipathing
  • Clustered Data ONTAP Path Changes
  • Selective LUN Mapping in Clustered Data ONTAP 8.3
  • Queue Depth
Module 14: SAN Management
  • Port and Logical Interface Management
  • LUN Management
  • LUN Mobility
  • Copy Offload
  • LUN Cloning
  • Protecting a LUN
  • Removing a LUN
Module 15: SAN Troubleshooting
  • SAN Troubleshooting
  • Data ONTAP Troubleshooting
  • NetApp Data Center Tools

Appendix A: Windows Miscellaneous

  • Windows Server 2012 CLI
  • Windows Server 2012 Server Core
  • Dynamic disks

Appendix B: Brocade Configuration

  • Fabric OS
  • Management IP address configuration
  • Setting configuration
  • Zone configuration

Appendix C: Cisco Configuration

  • NX-OS
  • Initial configuration
  • Port configuration
  • Zone configuration

Appendix D: Scalable SAN Failover

  • SAN architecture
  • SAN operations
  • CLAM quorum
  • Epsilon administration

Appendix E: SAN Migration

  • Foreign LUN import

New Features Addendum: ONTAP 9.1

  • ONTAP 9 introduction
  • ONTAP 9.1 highlights
  • 12-node SAN clusters
  • Simply anywhere
  • OTNAP select
  • OnCommand management portfolio
  • SAN management enhancements
  • All Flash FAS
  • SnapCenter 2.0
  • 9.1 hardware refresh
Labs
  • Verify the cluster from the CLI
  • Verify the cluster from OnCommand System Manager
  • Use the NetApp OnCommand System Manager to create a data aggregate
  • Use the NetApp OnCommand System Manager to create a subnet for an SVM
  • Use the NetApp OnCommand System Manager to create an SVM for iSCSI
  • Set up Multipath I/O on Microsoft Windows Server 2012 R2
  • Install the host utilities kit on Microsoft Windows Server 2012 R2
  • Configure iSCSI sessions on Microsoft Windows Server 2012 R2
  • Confirm iSCSI sessions on the data ONTAP operating system
  • Create a local administrative account for NetApp software
  • Install NetApp SnapDrive for Windows on Microsoft Windows Server 2012
  • Create a Window iSCSI disk with SnapDrive for Windows
  • Verify the Linux configuration
  • Install the NetApp Linux host utilities on your Linux system
  • Configure the iSCSI software initiator for Linux
  • Confirm the iSCSI connections
  • Enable the Linux native multipathing
  • Create iSCSI-attached LUNs for Linux
  • Discover iSCSI-attached LUNs for Linux
  • Prepare an individual LUN and mount it on Linux
  • Configure an LVM2 logical volume
  • Review key FC concepts
  • Investigate the initial switch configuration
  • Configure FC HBAs on a storage system
  • Configure an SVM for FC connectivity
  • Install QLogic FC tool on Windows 2012 R2 system
  • Enable FC HBA ports on a Windows 2012 R2 system
  • Assign aliases to WWPNs on a storage system
  • Provide LUN access by using the CLI
  • Create a Windows volume by using FC-attached NetApp LUNs
  • Create a VLAN on the switch
  • Configure a target FCoE port on the switch
  • Configure an initiator FC port on the switch
  • Set up one-to-one zone mapping between the initiator and target port
  • Install SnapDrive for Linux
  • Create a LUN by using SnapDrive for Linux
  • Use SnapDrive for Unix to recover data
  • Create an FC-attached LUN with system manager
  • Create a Snapshot copy of a LUN
  • Observe the effects of writing to a LUN
  • Observe the effects of deleting data from a LUN
  • Observe the effects of overwriting to a LUN
  • Observe the effects of setting a Snapshot automatic deletion policy
  • Review the key host considerations
  • Examine FC HBA port configuration
  • Expand and shrink a LUN
  • Clone a LUN for Windows
  • Copy and move a LUN
  • Remove a LUN from Windows
  • Reset the storage HBAS to initiator mode
  • Download nSANity
  • Examine nSANity commands
  • Collect system data
  • Viewing nSANity files
 

Accessing our website tells us you are happy to receive all our cookies. However you can change your cookie settings at any time. Find out more.   Got it!